Please
note - If you are not a qualified repair technician the members
of RepairHelper.com strongly recomends NOT trying to repair electrical
equipment as it is extremely dangerous and can lead to Harm or Death!
Please feel free to use our Repair Shop/Store Finder service to find qualified repair
technicians in your local area.
Back To Board |
|
Submitted By |
Mike
|
Date Posted |
9/30/2003 12:31:12 AM |
Title |
hitachi CT7883B (27IN) PLEASE HELP |
Message |
| Dear Sir
CT7883B Model number (27in)
This Tv when turn on just the relay clicks,no sound or picture.Check horz transistor Good).Please help.Thank you.tv man |
|
Submitted By |
R
|
Date Posted |
10/11/2003 6:13:31 PM |
Title |
RE: hitachi CT7883B (27IN) PLEASE HELP |
Message |
| Same Problem with a CT2043B |
|
Submitted By |
M
|
Date Posted |
10/28/2003 8:29:28 PM |
Title |
RE: hitachi CT7883B (27IN) PLEASE HELP |
Message |
| Greetings! I recently repaired such a set displaying the same problems. It was a 1991 Hitachi CT7883B which, when turned on, would begin horizontal scans plus part of one vertical scan. The vertical scan quickly diminishes and all that is left is a brief dot of phosphoressence at the center of the tube. The relay clicked, with no sound or picture. The fault was in the vertical scan circuitry: a faulty capacitor. The capacitor was a blue ceramic disk capacitor of capacitance 222K (as printed on the surface, not in farads, of course) at 2KV. In the television, it is located to the far left hand side of the pcb as you are looking down on it from the back of the set, and halfway down the side (closer to the front of the tube). I suggest you look at this capacitor as well as others in the vertical AND horizontal scan circuits, as they might be faulty and not the transistors. Keep in mind, most bad capacitors are visibly CRACKED OR CHARRED. More likely, cermaic disk capacitors would be cracked. Good luck. |
|
Submitted By |
M
|
Date Posted |
10/28/2003 8:31:45 PM |
Title |
RE: hitachi CT7883B (27IN) PLEASE HELP |
Message |
| In the above description, the (1/2) vertical and (several) horizontal scans last for less than one second as you turn the set on. It is enough to statically charge the crt, but NO IMAGE IS EVER FORMED, only a brief (less than 1 second) flash of phosphoressence occurs and then diminishes as if the set were turned off. |
|
Submitted By |
Raf
|
Date Posted |
12/8/2003 11:59:06 PM |
Title |
RE: hitachi CT7883B (27IN) PLEASE HELP |
Message |
"The capacitor was a blue ceramic disk capacitor of capacitance 222K (as printed on the surface, not in farads, of course) at 2KV."
I have the same problem. My capacitor is charred. Can you suggest a good place online to buy one? Or maybe give me a part number? I've tried, btu I can't find it anywhere. |
|
Submitted By |
Raf
|
Date Posted |
12/13/2003 9:54:19 PM |
Title |
RE: hitachi CT7883B (27IN) PLEASE HELP |
Message |
Bump... Anyone? |
|
|
Repairhelper Archives - Please note that this bulletin board is repairhelpers archived material and as such messages can no longer be replied to, but please feel free to browse this board for possible remedies to your repair questions.
Please goto Repairhelper.com to view our current 'Active' repair assistance board where you can post your own questions and browse our latest mssages/ replies.
|